Calculation of Lap length in Reinforced
Engineering

Calculation of Lap length in Reinforced

Homecivil May 20, 2022

Lap length is one of the important term in the reinforcement. This is usually confused with another important term called development length and anchorage length. In this article, the lap lengths of bars is discussed.

Calculation of Lap length in Reinforced

During the placement of steel in Reinforced concrete structure, if the required length of single bar may fall short. To get the desired design length, lapping of two bars side by side is done. An alternative to this is to provide mechanical couplers.

Calculation of Lap length in Reinforced

Lapping can be defined as the overlapping of two bars side by side to upto the design length. Usually, the stock length of steel bars is limited to 12m. This is for easy transportation of steel bars to the construction site. For example, imagine there is a need to build a 100ft tall column. But it’s not practically available. Hence the bars are cut every second story.

Calculation of Lap length in Reinforced

Then the tension forces are required to be transferred from one bar to the other bar at the location of discontinuity of the bar. So the second bar is kept closely to the first bar and overlapping is done. This amount of overlapping between two bars is called “lap length”. Lapping is usually done where minimum bending stress is encountered. In general, lap length is 50d which means 50 times the bar diameter, if both bars are of same diameter.

Calculation of Lap length in Reinforced

Lap length in tension:
The lap length including anchorage value of hooks shall be

  • For flexural tension – Ld or 30d whichever is greater is considered.
  • For direct tension – 2Ld or 30d whichever is greater is considered.
Calculation of Lap length in Reinforced

The straight length of lapping of bars shall not be less than 15d or 20cm.

Lap Length in Compression:
The lap length is equal to the development length calculated in compression but not less than 24d.

For Different Diameter Bars:
When the bars of different diameters are to be spliced, the lap length is calculated considering the smaller diameter bar.

Lap Splices

Lap splices should not be catered for the bars which are having diameter greater than 36 mm. In such cases, welding should be considered. But if welding is also not feasible in some conditions, then lapping may be allowed for the bars larger than 36 mm diameter. But along with lapping, additional spirals of 6 mm should be provided around the lapped bars.

Lap length for concrete of 1:2:4 Nominal mix:
The Lapping length in tension (MS bar – mild steel bar) including anchorage value is 58d. So eliminating the anchorage value, the lap length = 58d – 2*9d = 40d. (Where 9d = hook allowance up to 25 mm and k=2)

Lap length for M20 concrete:

  • Columns – 45d
  • Beams – 60d
  • Slabs – 60d

This infers that if we need to lap 20 mm diameter column bars, a minimum lap of 45 * 20 = 900 mm is provided

Share
Tweet
Email
Prev Article
Next Article

Related Articles

Wire Way in Electrical Work Sizing and Material Selection
Wire Way in Electrical Work Sizing and Material Selection. Cable …

Wire Way in Electrical Work Sizing and Material Selection

Corrupti quos dolores et quas molestias excepturi sint occaecati. Qui …

You Won’t Believe How Your Workspace Has Changed Over The Years… Wow.

About The Author

Homecivil

Leave a Reply

Cancel reply

  • Popular
  • Recent

Home Civil

About Us

Mattis ac condimentum sed, iaculis et dui. Integer non lectus luctus, sodales nulla in, blandit dolor.

Nullam quis dolor sed nisi sollicitudin vehicula ac sed magna. Praesent tincidunt facilisis nisl, sit amet suscipit tellus congue nec.

Archives

  • June 2022
  • May 2022
  • April 2022
  • September 2016
  • April 2016
  • March 2016
  • March 2014
Copyright © 2022 Home Civil
Theme by Homecivil.com

Ad Blocker Detected

Our website is made possible by displaying online advertisements to our visitors. Please consider supporting us by disabling your ad blocker.

Refresh